CPU - CPUE BOARDSHARDWARE
Ed. 04 11/12Réf. 3EH 21000 BSAA
CONNECTING A GENERAL BELL
The general bell is connected via the CENRG output of the AUDIO-OUT connector.
CONNECTING A BROADCAST LOUDSPEAKER
Broadcast loudspeakers are connected via the AUDOUT output of the AUDIO-OUT connector.
- Output impedance: < 500 Ohms
- Output level: access + 3 dBr
USING THE 12V OUTPUT
The GROUND and + 12V outputs on the AUDIO-OUT connector allow for the connection of an ex-
ternal 12V device with a maximum energy consumption of 150 mA (Rack 1 and Rack 2) or 300 mA
(Rack 3).
CenRg B
CenRg A
PROCESSING UNIT
CPU
Distribution panel
Power supply
General
call ringer
Aud Out B
Aud Out A
PROCESSING UNIT CPU
Distribution panel
Power supply
Amplifier