THIRD PARTY CTI - CSTA APPLICATIONS
Ed. 046/16 Réf. 3EH 21000 BSAA
- System reset:
• all the calls are lost
• the monitoring events are lost
- the monitoring requests are cancelled
The CTI server has to reconnect.
DEVICE IDENTIFIER
This paragraph describes the internal structure of the device identifiers used by the system's CSTA ser-
ver.
Static Device Identifier
As long as a device is not involved in a call, it is designated by its directory number. Thus, to establish
a call with "Make-Call", or request monitoring with "Monitor Start", the directory number of the device
concerned is used.
Dynamic Device Identifier
As soon as the device concerned is involved in a call, reference must be made to it in the connection
identifier, using the dynamic identifier. Thus, for a "Transfer-Call", the dynamic identifier obtained in
the previous events is used.
Label Length Dynamic identifier (4 bytes)
Label Length Connection identifier (10 bytes) .
Label Length Call identifier (2 bytes)