CALL METERING SERVICESAPPLICATIONS
Ed. 04 29/30Réf. 3EH 21000 BSAA
Flux control
Possibilities available in either instance – flux control of the terminal by the adapter and vice versa:
- Mode: none (no flux control), inband (control with 2 characters - XON and XOFF by default) or
circuit (control with the RTS and CTS signals)
- If Mode = inband, then decimal value for XON (17 by default) and XOFF (19 by default)
Implicit number of XON characters
This field defines the number of XON characters required to boot the equipment:
-Zero
-One
-Two
-Three
-Four
- XANY (non-significant option)
Echo
Check the box for a local or character by character echo in Command mode.
No input acknowledgement
Check the box to operate without V24 device input acknowledgements at the terminal.
Display caller address
Check the box to send the caller address to the terminal or DCE.
Escape sequence
This field defines a sequence of 3 characters maximum for switching the V24 device from CONNEC-
TED (data transmission) mode to COMMAND mode. Each character is defined by entering its decimal
value: the hexadecimal value and the character are displayed automatically.
Communication protocol
-Hayes
- Automatic
- V25 bis 108/1
- V25 bis 108/2