SYSTEM MESSAGES MAINTENANCE
Ed. 0410/24 Réf. 3EH 21000 BSAA
22 FLUX CONTROL ON A MEMORY
POOL
Exceeded size of memory alloca-
ted to flux control on a memory
pool
Board lo-
cation
INFO 0 = type of pool
INFO 1 = state (95 = exceeded
95 % threshold; 75 = gone un-
der 75 % threshold)
30 DBMS SUICIDE CPU (80) INFO 0 to 3 = causes of suicide
31 CURRENCY CONVERSION ->
EURO
CPU (80) INFO 0 = 1: conversion OK
32 PRIORITY CALL CPU (80) INFO 0, INFO 1 = number of
the set with which communica-
tion was lost in order to take a
priority call
56 ISDN BOARD FAULT
The ISDN protocol management
module detected a level 1 fault
on an ISDN access
Board lo-
cation.
Access
marker
INFO 0 = access status (0 = ac-
cess KO, 1 = access OK)
57 TEI DELETION CPU (80) INFO 0 = D-channel
INFO 1 = TEI
Analyze
the
reason
why the
TEI was
modified
by the
network
operator.
70 METERING SPOOLER K.O.
Message emitted by the spooler
when the metering buffer (the ar-
ray where the tickets are stored) is
n% full (70% by default)
Check the
printer
and its ca-
ble con-
nection
71 METERING SPOOLER O.K.
Message emitted by the spooler
when the metering buffer is
available again(-n% full; -70% by
default)
TYPE MESSAGE LOCA-
TION
ADDITIONAL INFORMATION ACTION