MAIN POWER SUPPLIES HARDWARE
Ed. 044/6 Réf. 3EH 21000 BSAA
BATTERIES
Equipment:
- Rack 1: 1 battery
- Rack 2: 2 batteries mounted in parallel
- Rack 3: 3 batteries mounted in series
Battery characteristics:
- sealed lead battery
- 1.2 Ah / 12 V
- fire resistance better than or equal to UL94-V2
Maintenance
To guarantee system shutdown without data loss in the event of a mains power failure or the mains
plug is unplugged at the wall socket, replace the batteries every two years. This maintenance operation
is vital to guarantee sufficient power autonomy to allow the files to be saved before the system shuts
down.
In the case of only voice module, (without Hard Disk or CoCPU board), the autonomy time is equal to
20 minutes.