7. From the Edit menu, choose Controller Properties.
The Controller Properties dialog box appears.
8. Click the Date/Time tab.
9. Check Enable Time Synchronization.
The motion modules set their clocks to the module you assign as the
Grandmaster.
10. Click OK.
IMPORTANT Check Enable Time Synchronization for all controllers that
participate in CIP Syncâ„¢. The overall CIP Sync network automatically
promotes a Grandmaster clock, unless the priority is set in the
Advanced tab.