Appendix A Specifications
A-32
Table A.3.11-2 CRU Output
Item Specifications
Output Mode
The signal output from CRU Output can be selected from Recovered Clock or
input signal.
The through output of the input signal can be output only when the input
signal is Clock.
Recovered Mode
When CRU Output is set to Recovery Clock
Amplitude
Typical 480 mVp-p
Clock Frequency
12.75 to 14.1 GHz (Half Rate Clock)
Additive Jitter
(RMS)
Typical 250 fs*
1,
*
2,
*
3
Max. 400 fs*
1,
*
4
Loop Bandwidth
Selectable from the list as follows.
4MHz
10MHz
Bitrate/1667
Attenuation: 20 dB/dec
Lock Detection
Detection function is available.
Through Mode
When CRU Output is set to Through
Amplitude
Typical 500 mVp-p
Operation
Frequency
0.1 to 1.7625 GHz (1.7625 GHz is the 1/16 Clock of 28.2 GHz)
Additive Jitter
(RMS)
Typical 200 fs*
3,
*
4,
*
5
Max. 400 fs*
4,
*
5
Connector
SMA, female
Termination
50
, AC coupled
Waveform Format
Square wave
*1: With 25.78125 Gbit/s, 26.5625 Gbit/s, and 28.05 Gbit/s, 1/4Clock
Pattern, Loop Bandwidth = 10 MHz, Single-ended, using MP2110A
PPG
*2: Input amplitude 400±100 mVp-p
*3: At 25±5°C
*4: Input amplitude 400 mVp-p
*5: With 25.78125 Gbit/s, 26.5625 Gbit/s, and 28.05 Gbit/s, 1/16Clock
Pattern, Single-ended, using MP2110A PPG