Digital inputs and outputs available for user:
Input
DI00
DI01
DI02
DI03
DI04
DI05
DI06
DI07
DI10
DI11
DI12
DI13
DI14
DI15
DI16
DI17
Output
DO00
DO01
DO02
DO03
DO04
DO05
DO06
DO07
DO10
DO11
DO12
DO13
DO14
DO15
DO16
DO17
Users can control the above IOs through the AUBOPE online programming. The general digital inputs and
outputs interface electrical parameters are as follows:
DI
Input form
Sink
No-voltage contact input
NPN open collector transistor
Input method
Input signal current
Electrical specifications
5mA/DC24V
DO
Output form
Transistor (Sink type)
Electrical specifications
300mA/DC24V
IO Specification
All AUBO robot IOs are set to NPN mode, which means low voltage level effective. When a User IO is set
to “Effectiveor “Highon the teach pendant, the actual voltage level at the IO output is low.
NoteOpen circuit protection is set in each IO. Therefore, whenever an IO is not connected in a closed
circuit, its output voltage is going to remain at high even if the IO is set to Effective by script or by
teach pendant.
For digital IO outputs, the method to check the IO status is to measure the resistance between DO and 0V.
When the DO is set to “Effectiveor “High”, the resistance goes to approximately 0Ω, otherwise the
resistance is about 12KΩ.
Analog input and output available for user:
Input
VI0
Analog voltage input
VI2
Analog voltage input
VI1
Analog voltage input
VI3
Analog voltage input
Output
VO0
Analog voltage output
CO0
Analog current output
VO1
Analog voltage output
CO1
Analog current output
Among them, the voltage inputs and outputs range are 0 ~ +10 V, accuracy of ± 1% and current output range