CLI Reference Guide 5. VoIP Commands
Version 6.4 115 January 2012
5.16.2.4 metering-tones
This command defines the metering tones.
Syntax:
# gw analoggw metering-tones
# set <parameter> <value>
The command’s syntax format is described below:
Arguments Description
<parameter> <value> Sets the following table parameters:
defaults
gen-mtr-tones
metering-type
For a description of these parameters, refer to the User's Manual.
Defaults
NA
Command Modes
Enable
Examples:
The following example sets the metering method for charging pulses.
(config-voip)# gw analoggw metering-tones
(gw-analgw-mtrtone)*# set metering-type 12-kHz-sinusoidal-bursts