CLI Reference Guide 5. VoIP Commands
Version 6.4 147 January 2012
5.26 Configuring In-band Signaling Settings
The following defines how to configure In-band Signaling settings.
5.26.1 media in-band-signaling
This command configures the media in-band-signaling table.
Syntax:
The syntax of this command includes the following variations:
media in-band-signaling
set <parameter> <value>
The command syntax format is described below:
Arguments Description
<parameter> <value> Sets the following table parameters:
COT-detector-enable
CPT-detector-frequency-deviation
DTMF-detector-enable
DTMF-generation-twist
DTMF-transport-type
DTMF-volume
IBS-detection-redirection
MF-transport-type
MFR1-detector-enable
MFR2-backward-detector-enable
MFR2-forward-detector-enable
NTT-DID-signaling-form
SIT-detector-enable
UDT-detector-frequency-deviation
call-progress-detector-enable
caller-ID-transport-type
caller-ID-type
defaults
digit-hangover-time-rx
digit-hangover-time-tx
telephony-events-max-duration
user-defined-tones-detector-enable
For a description of these parameters, refer to the User's Manual.