CLI Reference Guide  60  Document #: LTRT-17940 
  System and VoIP Functionalities 
Related Commands: 
show voip interface fxs-fxo 
The above commands give the user the interface status, main PM parameters and main 
configuration parameters. 
Examples:   
This example sets the metering method for charging pulses. 
(config-system)# interface fxs-fxo  
(fxs-fxo)# set metering-type 12-kHz-sinusoidal-bursts 
 
The following example enters a specific analog interface configuration. 
# show voip interface fxs-fxo 
Module in slot 1, Ports type is FXS 
Port 1 status: 
 Chip Revision: 2 
 Hook state(1- off hook, 0- onhook): 0 
 Message Waiting Indication: 0 
 Ring:0 
 Reversal Polarity:0 
 Tx Gain Control: 0db 
 Rx Gain Control: 0db 
Port configuration: 
Various timing parameters: 
 WinkTime 200 ms 
 CurrentDisconnectDuration 900 ms 
 FlashHookPeriod 700 ms 
 MinFlashHookTime 300 ms 
Caller ID and MWI parameters: 
 Primary Caller ID and MWI type is 0 
 AnalogCallerIDTimingMode is CallerID transferred between 
first and second rings 
 BellcoreCallerIDTypeOneSubStandard is 0 
 ETSICallerIDTypeOneSubStandard is 0 
 ETSIVMWITypeOneStandard is 0 
 BellcoreVMWITypeOneStandard is 0 
Various signal indications parameters: 
 PolarityReversalType is 0 
 MeteringType is 0 
 LifeLineType is acLifeLineType_Hardware_Only 
Country Coefficients is set to USA