6-6 Model D9854 Advanced Program Receiver Installation and Operation Guide 4021470 Rev D
PE n: Loss of
Input
Set Loss of input
detected
Cause: Loss of input.
Remedy: Ensure
input has a valid
stream.
Loss of input. Minor
Clear Fault reset
Digital Program
Mapping
Set PID Collision Cause: Uplink
settings may have
changed since setting
up the unit. Please
check your DPM
settings.
Remedy: Correct the
DPM settings. Check
the uplink to find the
appropriate system
settings.
Two source
service PIDs are
being mapped to
the same output
PID. This will
cause data
corruption in the
stream.
Minor
Program Collision Two source
channel numbers
are being
mapped/passed
to the same
channel number
in the output.
Mode-i PMT out of
range
PMT PID to be
used for Mode-i
is outside of
valid MPEG PID
range.
Clear Digital Program
Mapping - OK
Shutdown Event Set DL APP REBOOT Cause: User request
requires reboot or
internal system error.
Remedy: If it is an
internal system error
fault, clear alarms,
reset the unit, notify
customer service if
the problem persists.
New application
downloaded,
system requires
reboot.
Major
I2C Failure Internal system
error.
User requested FPGA
change
Runnable FPGA
change requires
reboot.
User requested APP
change
Runnable
application
change requires
reboot.