6-10 Model D9854 Advanced Program Receiver Installation and Operation Guide 4021470 Rev D
Flash STORAGE Set RECORD: init failed Cause: Hardware
issue.
Remedy: Clear
alarms, reset the unit,
and notify customer
service if the problem
persists.
Non-volatile
storage system
corrupted.
Possible loss of
configuration.
Major
RECORD
MANAGER: Record
contents check error,
erasing all
NVS Corruption,
and loss of
configuration
data
RECORD: sector
setup check error,
erasing sector
NVS Corruption,
and loss of sector
data
Clear RECORD: init done
LNB PS Set LNBPS: No Load Cause: Hardware
issue.
Remedy: Clear
alarms, reset the unit,
and notify customer
service if the problem
persists.
LNB power
overload
Minor
LNBPS: Over
Temperature
LNBPS: Over Loaded
LNBPS: Short Circuit
Clear LNBPS: Normal LNB power OK
LNBPS: Disabled
LNBPS: Off
Signal Quality Set Audio Muted due to
RF noise
Cause: RF Signal
quality is poor due to
interference or signal
level issues.
Remedy: Check RF
settings, re-aim dish,
and add signal
amplifier.
Signal is locked
but BER is
beyond Audio
muting
threshold.
Minor
Unstable RF Signal Signal lock
status is toggling
frequently.
Poor Quality RF
Signal
Signal is locked
but BER is
beyond muting
threshold.
Clear Signal Quality Fault
Cleared
Audio Unmuted
Alarm Message
Type
Message Cause/Remedy Description Severity

Table of Contents

Other manuals for Cisco D9854

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco D9854 and is the answer not in the manual?

Cisco D9854 Specifications

General IconGeneral
ModelD9854
CategoryReceiver
OutputASI, IP
DecodingMPEG-2
Conditional AccessBISS
Receiver TypeProfessional IRD
解密DVB-CSA, BISS, AES
Input Frequency Range950 MHz to 2150 MHz
Modulation FormatsQPSK, 8PSK