6-16 Model D9854 Advanced Program Receiver Installation and Operation Guide 4021470 Rev D
Messages, Continued
Warnings
The following table shows an alphabetical list of the available messages and their
default warning status.
Warning Message
Type
Message Cause/Remedy Description
ASI TS Overflow Set ASI Output Overflow Cause: Uplink settings may
have changed since setting
up the unit.
Remedy: Increase the
output rate, drop
unreferenced content in
DPM Options, and drop the
programs that are not
needed for downstream
devices. Contact your
(uplink) service provider to
verify the expected bit rate
settings.
The output rate is
higher than level set
by the user.
Clear ASI Output Overflow
Cleared
MPoIP TS Overflow Set MPEGoIP Output
Overflow
Cause: Uplink settings may
have changed since setting
up the unit.
Remedy: Increase the
output rate, drop
unreferenced content in
DPM Options, and drop the
programs that are not
needed for downstream
devices. Contact your
(uplink) service provider to
verify the expected bit rate
settings.
The output rate is
higher than the level
set by the user.
Clear MPEGoIP Output
Overflow Cleared