6-18 Model D9854 Advanced Program Receiver Installation and Operation Guide 4021470 Rev D
Temperature
Warning
Set Temperature over
Warning threshold
Cause: Room temperature
too high, or air flow is
blocked.
Remedy: Check openings
on front and rear panels for
blockage. Lower the room
temperature or improve air
flow to the device.
Temperature is above
normal operating
range.
Clear Temperature normal
FPGATemperature
Warning
Set Temperature over
Warning threshold
Cause: Room temperature
is too high, or air flow is
blocked.
Remedy: Check the
openings on front and rear
panels for blockage. Lower
the room temperature or
improve air flow to the
device.
FPGA temperature is
above normal
operating range.
Clear Temperature normal
TDT timeout # Set tdt timed out Cause: Uplink is not
sending or is sending
intermittently.
Remedy: Clear warning. If
the problem persists,
determine if uplink is
sending the current SI
information table. Disable
the warning if not using the
table.
Time Date Table was
never received.
tdt is lost No longer receiving
Time Date.
Clear tdt fault cleared
SDT timeout # Set sdt # timed out Cause: Uplink is not
sending or is sending
intermittently.
Remedy: Clear warning. If
the problem persists,
determine if uplink is
sending the current SI
information table. Disable
the warning if not using the
table.
Service Description
Table was never
received.
sdt # is lost No longer receiving
Service Description.
Clear sdt fault cleared
Warning Message
Type
Message Cause/Remedy Description