6-20 Model D9854 Advanced Program Receiver Installation and Operation Guide 4021470 Rev D
DRT timeout # Set drt # timed out Cause: Uplink is not
sending or is sending
intermittently.
Remedy: Clear warning. If
the problem persists,
determine if uplink is
sending the current SI
information table. Disable
the warning if not using the
table.
Disaster Recovery
Table was never
received.
drt # is lost No longer receiving
Disaster Recovery
Table.
Clear drt fault cleared
MCT Timeout # Set mct # timed out Cause: Uplink is not
sending or is sending
intermittently.
Remedy: Clear warning. If
the problem persists,
determine if uplink is
sending the current SI
information table. Disable
the warning if not using the
table.
Inband Control Table
was never received.
mct # is lost No longer receiving
Inband Control
Table.
Clear mct fault cleared
ECT Timeout # Set ect # timed out Cause: Uplink is not
sending or is sending
intermittently.
Remedy: Clear warning. If
the problem persists,
determine if uplink is
sending the current SI
information table. Disable
the warning if not using the
table.
Event Control Table
was never received.
ect # is lost No longer receiving
Event Control Table.
Clear ect fault cleared
Memory Usage Host Set Excessive (stack/
partition) memory
usage
Cause: Possible software
issue.
Remedy: Clear warnings,
reset the unit, and notify
customer service if the
problem persists.
SW exceeding
allowable memory
usage.
Clear Normal (stack/
partition) memory
usage
Warning Message
Type
Message Cause/Remedy Description