GR712RC-UM, Jun 2017, Version 2.9 197 www.cobham.com/gaisler
GR712RC
Read:
Information obtained from coding layer.
[2]
18: 16 CSEC (Count of Single Error Corrections) (see [PSS-04-151])
Write: Don’t care.
Read: Information obtained from coding layer.
15: 14 RESERVED
Write: Don’t care.
Read: All zero.
13: 11 SCI (Selected Channel Input) (see [PSS-04-151])
Write: Don’t care.
Read: Information obtained from coding layer.
10: 0 RESERVED
Write: Don’t care.
Read: All zero.
Power-up default: 0x00003800
Table 212. CLCW Register (CLCWRx) (see [PSS-04-107])
31 30 29 28 26 25 24 23 18 17 16 15 14 13 12 11 10 9 8 7 0
CWTY VNUM STAF CIE VCI RESERVED NRFA NBLO LOUT WAIT RTMI FBCO RTYPE RVAL
31 CWTY (Control Word Type)
30: 29 VNUM (CLCW Version Number)
28: 26 STAF (Status Fields)
25: 24 CIE (COP In Effect)
23: 18 VCI (Virtual Channel Identifier)
17: 16 Reserved (PSS/ECSS requires “00”)
15 NRFA (No RF Available)
Write: Don’t care.
Read: Based on discrete inputs TCRFAVL[4:0], where the inputs are OR-ed
14 NBLO (No Bit Lock)
Write: Don’t care.
Read: Based on discrete inputs TCACT[4:0], where the inputs are OR-ed
13 LOUT (Lock Out)
12 WAIT (Wait)
11 RTMI (Retransmit)
10: 9 FBCO (FARM-B Counter)
8 RTYPE (Report Type)
7: 0 RVAL (Report Value)
Power-up default: 0x00000000
Table 213. Physical Interface Register (PHIR)
[7]
31 16 15 8 7 0
RESERVED RFA BLO
31: 16 RESERVED
Write: Don’t care.
Read: All zero.
15: 8
RFA (RF Available)
[3]
Only the implemented inputs 0 through 4 are taken into account. All other bits are zero.
Write: Don’t care.
Read: Bit[8] = input 0, Bit[15] = input 7
Table 211. Frame Acceptance Report Register (FAR)
[7]