InteliDrive Lite, SW version 1.9  
ID-FLX-Lite-1.9r1 Reference Guide.pdf, ©ComAp – August 2015   
14.11  IL-NT RS232-485 (optional card) 
Plug-in into InteliDrive Lite controller COMMUNICATION MODULE port. 
 
Maximal distance        10m (RS232), 1200m (RS485) 
Maximum Speed         Up to 57.6 kBd (DIRECT), 38.4kBd Analog modem, 
9.6 kBd digital modem, 57.6 kBd (MODBUS) 
14.12  IL-NT S-USB (optional card) 
Plug-in into InteliDrive Lite controller COMMUNICATION MODULE port. 
 
Maximal distance         5m 
Maximum Speed         Up to 57.6 kBd (DIRECT), 38.4kBd Analog modem, 
9.6 kBd digital modem, 57.6 kBd (MODBUS) 
 
Use only shielded A-B USB cables up to 5m length. 
 
Recommend USB cable: 
USB-LINK CABLE 1.8M - ComAp A-B USB cable. 
14.13  IB-Lite (optional card) 
Plug-in into InteliDrive Lite controller COMMUNICATION MODULE port. 
 
10/100 MBit ethernet interface in RJ45 socket. 
14.14  IL-NT GPRS (optional card) 
Plug-in into InteliDrive Lite controller COMMUNICATION MODULE port. 
 
GSM/GPRS modem 
Quad Band         850/900/1800/1900MHz 
GPRS multi-slot       class 10 
CSD communication      up to 14.4kbps 
TCP/IP communication      over GPRS 
Voltage supply 8-36VDC 
14.15  IL-NT AOUT8 (optional card) 
Plug-in into InteliDrive Lite controller EXTENSION MODULE port. 
 
Number of PWM outputs       8 
PWM frequency         1200Hz 
Maximum current         0,5A 
Maximum switching voltage       36VDC 
Output resistance         1Ohm 
Resolution           10bits