CDM-840 Remote Router MN-CDM840
Serial-based Remote Product Management Revision 3
7–19
Parameter
Type
Description of Arguments
(Note that all arguments are ASCII numeric codes from 48 and 57)
Response to Query
(Target to Controller)
NOTE: VALID ONLY WHEN THE FSK AND BUC POWER ARE ON.
Returns the BUC Phase Lock Loop in the form x, where:
0=Locked
1=Unlocked
9=Not connected
EXAMPLE: <0/BPA?[cr]
>0000/BPA=1[cr][lf]
(see Description of
Arguments)
NOTE: VALID ONLY WHEN THE FSK AND BUC POWER ARE ON.
Returns the power level, in watts, for C-Band and Ku-Band in the form xx,
where:
1=2 watts
2=4 watts
3=5 watts
4=8 watts
5=10 watts
6=16 watts
7=20 watts
8=25 watts
9=40 watts
10=60 watts
EXAMPLE: <0/BPC?[cr]
(see Description of
Arguments)
Sets or returns the BUC Power Supply control in the form x, where:
0=Disable
1=Enable
(see Description of
Arguments)
NOTE: VALID ONLY WHEN THE FSK AND BUC POWER ARE ON.
Returns the BUC Software Version in the form xx, where:
xx=0 or 15
EXAMPLE: <0/BSV?[cr]
(see Description of
Arguments)