Parameter
Type
Description of Arguments
(Note that all arguments are ASCII numeric codes from 48 and 57)
Response to Query
(Target to Controller)
for Internal
10MHz High-
stability
Reference
Sets or returns the fine adjustment of the Internal 10MHz Reference on the
High-Stability Frequency Reference module in the form sddd, where:
s=sign [– (negative) or + (positive)]
ddd=value from 0 to 999.
(see Description of
Arguments)
Sets or returns the user-defined Circuit ID string, which is 4 to 32 characters in
length.
NOTE: Valid characters include Space ( ) * + – , . / 0 thru 9 and A thru Z
EXAMPLE: <0/CID=RxCircuitID[cr]
(see Description of
Arguments)
NOTE: THIS COMMAND TAKES NO ARGUMENTS.
Resets the admin username/password to:
Username=“comtech”
Returns firmware information for Image 0, 1 or 2, where:
0=Bootrom Information
1=Image #1 Firmware Information
2=Image #2 Firmware Information
The information return in the form xxxxx…,mm/dd/yy where:
xxxxx…=The firmware number
mm/dd/yy=The firmware date in month/date/year
(see Description of
Arguments)
Sets the geographical log information in the form
AAAAOOOOOXNNNNNNNN, where:
AAAA=Latitude
OOOOO=Longitude
X=exclusion zone status (0 or 1)
NNNNNNNN=name of satellite used
NOTE: Data is stored in the file “GPS.log.” Data in the log file older than one
year is removed from the log file. The format of the text in the log file is a
single GLG command per line:
WWWWSSSSSSSSFFFFFFFFBBBBBBBBMAAAAOOOOONNNNNNNN,
NNNNNNN
(see Description of
Arguments)