CDM-570A/570AL Satellite Modem with Optional Packet Processor
Revision 5
Serial-based Remote Product Management 8–30 MN-CDM570A
Parameter
Type
Command
(Instruction
Code and
Qualifier)
Arguments for
Command or
Response to
Query
Description of Arguments
Response to
Command
Query
(Instruction Code
and Qualifier)
Response to
Query
Retrieve Next 5
unread stored
Statistics
(continued)
For IP-ACM mode:
{CR}Sub-body{CR}Sub-body{CR}Sub-body{CR}Subbody{CR}Sub-body
where Sub-body = AA.ABB.BC,DE,Fddmmyyhhmmss:
AA.A=Minimum Eb/No during sample period.
BB.B=Average Eb/No during sample period.
C=IP-ACM Rx ModCod that was current at time the statistic entry was logged.
D=Maximum Rx ModCod in hex during sample period.
E=Minimum Rx ModCod in hex during sample period.
ddmmyyhhmmss = date/time stamp.
Notes:
1) If there are no new events, the unit response is RNS*.
2) If less than 5 statistics are to be retrieved, the remaining positions are padded
with zeros.
3) If you change your operating mode between non-IP-ACM and IP-ACM modes,
Comtech EF Data recommends that you execute the Clear All stored Statistics
(CAS=) command before retrieving any further statistics.
1:1 Operational
Mode
ASW=
1 byte,
value of 0 or 1
Command or Query.
Sets or returns 1:1 operational mode in the form x, where
0 = Unit is in Manual Mode
1 = Unit is in Auto Mode
Note: In Manual Mode, all fault relays are forced to the non-faulted condition. This
allows the online unit to be configured without an unintended switchover to the
backup unit.
ASW=
ASW?
ASW*
ASW#
ASW?
ASW=x
(see Description of
Arguments)
Force 1:1 Switch
FSW=
None
Command only.
This command takes no arguments.
Forces the unit to toggle the Unit Fail relay to the ‘fail’ state for approximately
500ms. If the unit is part of a 1:1 pair and it is currently the ‘On Line’ unit, this
forces a switchover, so the unit is then be in ‘Standby’ mode.
Notes:
1) The 1:1 redundancy system must be installed.
2) Both online and offline units must be in Manual Mode for this command to
function.
3) If the 1:1 redundancy system is not installed, then the command returns FSW?
4) If the unit is offline, then the command will return FSW?
FSW= (message
OK)
N/A
N/A