EasyManua.ls Logo

CUMMINS N14 - Variable Speed (VS) Governor Speed Not Set Correctly

CUMMINS N14
812 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Variable Speed (VS) Governor Speed Not Set Correctly
Cause Corrections
----------
PT Fuel Pump Lower (Automotive)
Throttle Lever is Not Locked Wide
Open
OK
f
Make sure the lower lever linkage opens
the throttle wide open. Refer to Procedure
5-02.
----------
PT Fuel Pump Variable Speed Governor
Linkage is Not Fully Open or is Set to Idle
OK
f
Adjust the throttle linkage. Refer to
Procedure 5-02.
----------
PT Fuel Pump Low Speed Set Screw is
Out of Adjustment
OK
f
Loosen lock nut and adjust the rear screw.
Refer to Procedure 5-05 and the PT Fuel
Pump Rebuild and Calibration Manual,
Bulletin No. 3379084.
----------
PT Fuel Pump High Speed Spring is Incorrect
OK
f
Remove PT fuel pump and change the
spring. Refer to Procedure 5-02 and the PT
Fuel Pump Rebuild and Calibration Manual,
Bulletin No. 3379084.
----------
PT Fuel Pump Lever Screw Does Not
Let The Throttle Lever Plunger Move
Remove PT fuel pump. Inspect the screw
adjustment. Refer to Procedure 5-02 and the
PT Fuel Pump Rebuild and Calibration
Manual, Bulletin No. 3379084.
Troubleshooting Symptoms Charts SectionT-Troubleshooting
N14Page T-104

Table of Contents

Other manuals for CUMMINS N14