Install coolant sightglass analyzer, Part No. 3823211, to
the engine block pressure and water pump inlet pressure
CompuchekT fittings.
NOTE: The needle valve (1) on the coolant sightglass an-
alyzer, Part No. 3823211, must be installed on the block
pressure side of the sightglass (2).
NOTE: The coolant sightglass analyzer, Part No. 3823211,
must be full of water or coolant before the test is begun. Air
in the analyzer can lead to false indications of air in the
cooling system. To fill the analyzer with coolant, do the
following:
Installa male quick connect fitting,Part No. 3377244
or 3377245, into the water pump inlet pressure side
of the analyzer.
Place the water pump inlet pressure side of the
analyzer in a bucket.
Open the needle valve on the analyzer.
Install the block pressure side of the analyzer to the
engine.
After the analyzer is full of coolant, disconnect the
male quick connect and continue with the test.
Cooling System - Testing For Air Or Combustion Gases (1-10) Section 1 - Cooling System