AccuVision
®
AV6010 Long-Range Camera System Manual Chapter 5 105
05-AV6010_Setup_R10.doc Accu-Sort Systems, Inc.
Setup Camera Image Viewer
1. Launch the Camera Image Viewer.
(To perform SBS setup, version 6.0 is required.)
2. In the View drop-down menu, select both Show Extra Information and
View SBS Information.
3. Set the Cam IP to match the IMAGE port IP address of the top-read
AV6010 camera.
4. Set the IDS IP to match the IP address of your laptop.
5. In the IDS drop-down menu, confirm that Enabled is checked and that
Delete Image After Viewing is NOT checked. This allows images to be
saved to the laptop.
6. Click the Enable VisionCapture button at the top right-hand of the
viewer.
7. Go to the Tools drop-down menu and enable Side-by-Side Detection.
8. Confirm Down Sample is set to 16.
9. On the viewer’s Side-by-Side Setup tab, click the Read Parameters
from Camera button. This gets the current parameters from the camera.
10. Select the transport type. (See Setup for Transport Type.)
11. Confirm that the following are enabled (checked):
Post Process Displayed Images
Crop Images to Image Valid
12. Continue SBS setup with Capture Images.