PA.59 Protection upon
load becoming 0
0:Disabled
1:Enabled
1 0 ○
PA.60 Detection level
of load becoming
0
0.0~100.0% 0.001 10.0% ○
PA.61 Detection time of
load becoming 0
0.0~60.0s 0.1s 1.0% ○
PA.63 Over-speed
detection value
0.0%~50.0%(Maximum
frequency)
0.1% 20.0% ○
PA.64 Over-speed
detection time
0.0s:Not detected
0.1~60.0s
0.001 1.0s ○
PA.65 Detection value
of too large
speed deviation
0.0%~50.0%(Maximum
frequency)
0.1% 20.0% ○
PA.66 Detection time of
too large speed
deviation
0.0s: Not detected
0.1~60.0s
0.001 5.0s ○
Group PB: Multi-Reference and Simple PLC Function
Function
Code
Parameter
Name
Setting Range Minimum
Unit
Default Property
Pb.00 Multi-reference 0 -100.0% ~ 100.0%(100.0% to
maximum frequency P0.05)
0 0.0% ○
Pb.01 Multi-reference 1 -100.0%~100.0% 0 0.0% ○
Pb.02 Multi-reference 2 -100.0%~100.0% 0 0.0% ○
Pb.03 Multi-reference 3 -100.0%~100.0% 0 0.0% ○
Pb.04 Multi-reference 4 -100.0%~100.0% 0 0.0% ○