220
Pb.19 Acceleration/deceleration time of
simple PLC reference 0
Setting Range: 03 0
Pb.20~46
(even)
Running time of simple PLC
reference n
Setting Range:
0.0s(h)6553.5s(h)
0.0s(h)
Pb.21~46
(singular)
Acceleration/deceleration time of
simple PLC reference n
Setting Range: 03 0
P b.48 Running time of simple PLC
reference 15
Setting Range:
0.0s(h)6553.5s(h)
0.0s(h)
Pb.49 Acceleration/deceleration time of
simple PLC reference 15
Setting Range: 03 0
Pb.50 Time unit of simple PLC running Setting Range: 01 0
0: s(second) 1: h(hour)
P b.51 Reference 0 source Setting Range: 05 0
0 set by PA.00 1 2: VI CI 4 PULSE setting 5 PID 6 Set by preset
frequency
It determines the setting channel of reference 0. You can perform convenient switchover
between the setting channels. When multi-reference or simple PLC is used as frequency
source, the switchover between two frequency sources can be realized easily.
6.13 Communication Parameter Group PC
Please refer to chapter 9 YX-9000 RS485 communication protocol
6.14 Function Code ParameterGroup Pd
Pd.00
User password
Setting Range: 0