113
PC.02 Local address 0 Broadcast address
1247
Valid for
MODBUSProfibus-
DPCANlink
1 1
PC.03 Response delay 020ms(Valid for
MODBUS
1ms 2
PC.04 Communication
timeout
0.0Invalid
0.1:~60.0s
0.1s 0.0
PC.05 Modbus protocol
data format
MODBUS
0Non-standard Modbus
protocol
1Standard Modbus protocol
1 0
Group Pd: Function Code Management
Function
Code
Parameter
Name
Setting Range Minimum
Unit
Default Property
Pd.00 User password 065535 1 0
Pd.01 Restore default
setting
0No operation
01Restore factory setting,
except motor parameters
02Clear records
1 0 ×
Pd.02 AC drive
parameter
display selection
Unit’s digitGroup b display
selection
0Not display
1Display
Ten’s digit: Group E display
selection
1 001 ×