159
21Acceleration/Deceleration prohibited
It enables the AC drive to maintain the current frequency output without being affected by
external signals (except the STOP command).
22PID pause
PID is invalid temporarily. The AC drive maintains the current frequency output without
supporting PID adjustment of frequency source.
23PLC status reset
The terminal is used to restore the original status of PLC control for the AC drive when PLC
control is started again after a pause.
24Swing pause
The AC drive outputs the central frequency, and the swing frequency function pauses.
25Counter input
This terminal is used to count pulses
26Counter reset
This terminal is used to clear the counter status.
27Length count input
This terminal is used to count the length, for details, see PE.05 and PE.06 description.
28Length reset
This terminal is used to clear the length (PE.06).