21:Acceleration/Deceleration prohibited
It enables the AC drive to maintain the current frequency output without being affected by
external signals (except the STOP command).
22:PID pause
PID is invalid temporarily. The AC drive maintains the current frequency output without
supporting PID adjustment of frequency source.
23:PLC status reset
The terminal is used to restore the original status of PLC control for the AC drive when PLC
control is started again after a pause.
24:Swing pause
The AC drive outputs the central frequency, and the swing frequency function pauses.
25:Counter input
This terminal is used to count pulses。
26:Counter reset
This terminal is used to clear the counter status.
27:Length count input
This terminal is used to count the length, for details, see PE.05 and PE.06 description.
28:Length reset
This terminal is used to clear the length (PE.06).
32:Immediate DC braking