AO1 AO1 terminal current/
voltage selection
Current selection :AO2: 0~20mA or
4~20mA output
Voltage selection :AO2: 0~10V output
0-10V
AO2 AO2 terminal current/
voltage selection
Current selection :AO2: 0~20mA or
4~20mA output
Voltage selection :AO2: 0~10V output
0-10V
CI CItermial current/ voltage
input selection
Current selection :CI: 0~20mA or
4~20mA input
Voltage selection :CI: 0~10V input
0-10V
3.6.2 Description of Terminals on Control Circuit
(1) Function of CN 1 terminal shown as Table 3-3
Table 3-3 CN 1 t
erminal function
Sort
Terminal
Name Function Description Specification
Relay
output
terminal
TA/RA Multi
functi
onal
relay
output
terminal
Can be defined as
multifunctional
Relay output terminal by
programming, refer to Chapter
6.5 P4.02, P4.03
TA-TC: NC, TA-TB: Normal open
contact capacity AC250V/2A
(COSΦ=1)
AC250V/1A (COSΦ=0.4)
DC30V/1A
TB/RB
TC/RC
(2) Control Circuit CN2 terminal shown as Fig.3-7
485-
485+ 10V
X1
AO1
1
GND
X3
X2CI
GN
D
VI
COM
M
COM
24V
FM
OP
PE
DO1CME
AO
2
X4 X5 X6
X7