94
3: SIN/COS encoder
4:Wire-saving UVW encoder
P8.29 Reserved
P8.30 A,B phase
sequence of ABZ
incremental
encoder
0:Forward
1:Reverse
1 0 ×
P8.31 Encoder
installation angle
0.0~359.9° 0.1° 1 ×
P8.32 U,V,W phase
sequence of
UVW encoder
0:Forward
1:Reverse
1 0 ×
P8.33 UVW encoder
angle offset
0.0~359.9° 0.1° 0.0° ×
P8.34 Number of pole
pairs of resolver
1~65535 1 1 ×
P8.37 Auto-tuning
selection
0: No auto-tuning
1:Asynchronous motor static
auto-tuning
2:Asynchronous motor with-
load auto-tuning
1 0 ×
Group P9: Vector Control Parameters
Function
Code
Parameter
Name
Setting Range Minimum
Unit
Default Property
P9.00 Speed/Torque
control mode
0:Speed control 1:
Torque control
1 0 ×

Table of Contents