228
They have been corrected upon delivery. When you resume the factory values, these
parameters will be restored to the factory-corrected values. Generally, you need not perform
correction in the applications.
Measured voltage indicates the actual output voltage value
measured by instruments such as the multimeter. Displayed
voltage indicates the voltage display value sampled by the AC
drive.
PF.16 AO2 target voltage 1 Setting Range:
0.500 V4.000 V
Factory-corrected
PF.17 AO2 measured voltage 1 Setting Range:
0.500 V4.000 V
Factory-corrected
PF.18 AO2 target voltage 2 Setting Range:
6.000V9.999V
Factory-corrected
PF.19 AO2 measured voltage 2 Setting Range:
6.000V9.999V
Factory-corrected
Corrected method is the same with AO1.
PF.36 Jump point of VI input
corresponding setting
Setting Range:
-100.0%100.0%
0.0%
PF.37 Jump amplitude of VI input
corresponding setting
Setting Range:
0.0%100.0%
0.5%
PF.38 Jump point of CI input
corresponding setting
Setting Range:
-100.0%100.0%
0.0%
PF.39 Jump amplitude of CI input
corresponding setting
Setting Range:
0.0%100.0%
0.5%