197
If the AC drive is in the stop state, the load speed is the speed
corresponding to the set frequency, namely, "set load speed". If
the set frequency is 50.00 Hz, the load speed in the stop state is
50.00 x 2.000 = 100.00 (display of 2 decimal places).
P7.12
Accumulative power-on time
Setting Range
0h65535h
0h
It is used to display the accumulative power-on time of the AC drive since the delivery.
If the time reaches the set power-on time (P2.16), the terminal
with the digital output function 24 becomes ON.
P7.13
Accumulative power
consumption
Setting Range
065535 kWh
0
It is used to display the accumulative power consumption of the AC drive until now.
6.9 Motor ParametersGroup P8
P8.00
Motor type selection
0Common
asynchronous motor
1Variable frequency
asynchronous motor
0
P8.01
Rated motor power
Setting Range:
0.1KW1000.0KW
Model
dependent
P8.02
Rated motor voltage
Setting Range: 02000V Model
dependent
P8.03
Rated motor current
Setting Range:
0.01A655.35 A
Model
dependent
P8.04
Rated motor frequency
Setting Range: 0.01HZ to Model