EasyManua.ls Logo

degdrive DGI900 - Description of Function Codes; Basic Parameters (Group P0); Fault and Protection (Group PA)

degdrive DGI900
251 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
98
frequency in
torque control
mode
P9.30 Acceleration
time of torque
control
0.00s65000s 0.01s 0.00s
P9.31 Deceleration
time of torque
control
0.00s65000s 0.01s 0.00s
Group PA: Fault and Protection
Function
Code
Parameter
Name
Setting Range Minimum
Unit
Default Property
PA.00 Motor overload
protection
selection
0: Disabled
1: Enabled
1
PA.01 Motor overload
protection gain
0.2010.00 1.00
PA.02 Motor overload
protection
coefficient
50%100% 80%
PA.03 Over voltage
stall gain
0100 0
PA.04 Over voltage
stall protective
current
120%150% 130%
PA.05 Over current stall 0100 20

Table of Contents