P3.43 AI as valid status
selection of DI
0High level valid
1Low level valid
Unit’s digitVI
Ten’s digitCI
111 111 ×
Group P4: Output Terminals
Function
Code
Parameter
Name
Setting Range Minimum
Unit
Default Property
P4.00 FM terminal
output mode
0Pulse output (FMP)
1Switch signal
outputFMR
1 0
P4.01 FM
function(open-
collector output
terminal)
0No output
1AC drive running
2Fault output (stop)
3Frequency-level detection
FDT1 output
4Frequency reached
5Zero-speed running(no
output at stop)
6Motor overload pre-
warning
7AC drive overload pre-
warning
8Set count value reached
9Designated count value
reached
1 0
P4.02 Relay function
T/A-T/B-T/C
1 2
P4.03 Extension card
relay
functionR/A-
R/B-R/C
1 0
P4.04 DO1 function
selection
(Reserved)
1 1

Table of Contents