degdrive DGI900 - Base Frequency for UP;DOWN Modification During Running; Binding Command Source to Frequency Source

degdrive DGI900
251 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
130
▲and▼ or the terminal UP/DOWN function is cleared.
1 Retentive” If P0-22 is set to 1, the digital setting frequency value is the set
frequency at the moment when the AC drive stops. The modification by using keys and
▼ or the terminal UP/DOWN function remains effective.
P0.23
Base frequency for UP/DOWN
modification during running
Setting Range
01
0
0Running frequency1Set frequency.
This parameter is valid only when the frequency source is digital setting.
It is used to set the base frequency to be modifie
d by using keys and or the
terminal UP/DOWN function. If the running frequency and set
frequency are different, there will be a large difference between
the AC drive's performance during the acceleration/deceleration
process.
P0.24
Binding command source
to frequency source
Setting Range0000
9999
0000
Unit's digit: Binding operation panel command to frequency source.
Ten's digit: Binding terminal command to frequency source.
Hundred's digit: Binding communication command to frequency source.
Thousand’s digit: Binding automatic running command to frequency source
It is used to bind the four running command sources with the nine frequency sources,
facilitating to implement synchronous switchover.