(2) Noise Suppression Methods
Path Noise suppression methods
If a closed loop is formed between the peripheral equipment and the inverter
wiring,the grounding leakage of the inverter will misoperate the equipment.
Solution: Remove the grounding of the peripheral equipment.
When peripheral equipment share the same power source with the inverter, the
noise transmitted through the power line may misoperate the peripheral
equipment.
Solution: Mount a noise filter at inverter input side or isolated the peripheral
equipment with an isolated transformer or power filter.