P0.19 Frequency source
selection
Unit’s digit:(Frequency
spurce selection)
0:Main frequency source 1
1:1 and 2 operation
(operation relationship
determined by ten’s digit)
2:Switchover between 1 and
2
3:Switchover between 1 and
“1 and 2 operation”
4:Switchover between 2 and
“1 and 2 operation”
Ten’s digit (1 and 2 operation
relationship)
0:1+2
1:1 - 2
2:Maximum
3:Minimum
01 00 ○
P0.20 Frequency offset of
auxiliary frequency
source for 1 and 2
operation
0.00Hz to maximum
frequency (P0.05)
0.01HZ 0.00HZ ○
P0.21 Frequency
reference resolution
1:0.1Hz
2:0.01Hz
1 2 ×
P0.22 Retentive of digital
setting frequency
upon power failure
0: Not retentive
1:Retentive
1
0 ○