68
P2.14 Running mode
when set
frequency lower
than frequency
lower limit
0Run at frequency lower
limit
1Stop
2Run at zero speed
0 0
P2.15 Drop control 0.00HZ10.00HZ 0.01HZ 0.00HZ
P2.16 Accumulative
power-on time
threshold
0h65000h 1h 0h
P2.17 Accumulative
running time
threshold
0h65000h 1h 0h
P2.18 Startup
protection
0NO 1YES 1 0
P2.19 Frequency
detection value
(FDT1)
0.00Hz to maximum frequency 0.01Hz 50.00Hz
P2.20 Frequency
detection
hysteresis
(FDT1)
0.0%100.0%(FDT1 level) 0.1% 5.0%
P2.21 Detection range
of frequency
reached
0.0%100.0% ( maximum
frequency)
0.1% 0.0%
P2.22 Jump frequency
during
acceleration
0Disabled 1Enabled 1 0