amplitude
P2.38 Any current
reaching 2
0.0 %~300.0 %(100.0% rated
motor current)
0.1% 100.0 % ○
P2.39 Any current
reaching 2
amplitude
0.0 %~300.0 %(100.0% rated
motor current)
0.1% 0.0 % ○
P2.40 Timing function 0:Disabled 1:Enabled 1 0 ○
P2.41 Timing duration
selection
0: P2.42 setting
1:VI
2:CI
1 0 ○
P2.42 Timing duration 0.0Min~6500.0Min 0.1Min 0.0Min ○
P2.43 VI input voltage
lower limit
0.00V~P2.44 0.01V 3.10V ○
P2.44 VI input voltage
upper limit
P2.44~10.00V 0.01V 6.80V ○
P2.45 Module
temperature
threshold
0~100℃ 1 75℃ ○
P2.46 Cooling fan
control
0:Fan working during running
1:Fan working continuously
1 0 ○
P2.47 Wakeup
frequency
Dormant frequency(P2.49)
~maximum frequency
0.01HZ 0.00HZ ○
P2.48 Wakeup delay
time
0.0S~6500.0S 0.1S 0.0S ○
P2.49 Dormant
frequency
0.00Hz to wakeup frequency
P2.47
0.01HZ 0.00HZ ○
P2.50 Dormant delay 0.0S~6500.0S 0.1S 0.0S ○