81
P4.06 FMP function
selection
0:Running frequency
1:Set frequency
2:Output current
3:Output torque
4:Output power
5:Output voltage
6:Pulse input(100.0% at
100.0KHZ)
7:VI
8:CI
10:Length
11:Count value
12:Communication setting
13:Motor rotational speed
14:Output current(100.0%
at 1000.0A)
15:Output voltage(100.0%
at 1000.0V)
16:Output torque(actual
value)
1 0 ○
P4.07 AO1 function
selection
1 0
P4.08 AO2 function
selection
1 1
P4.09 Maximum FMP
output frequency
0.01KHZ ~ 100.00KHZ 0.01KHZ 50.00KH
Z
○
P4.10 AO1 offset
coefficient
-100.0% ~ +100.0% 0.001 0.0% ○
P4.11 AO1 gain -10.00 ~ +10.00 0.01 1.00 ○
P4.12 AO2 offset
coefficient
-100.0% ~ +100.0% 0.001 0.0% ○