Configuring network interfaces Configure serial interfaces
Digi TransPor Routers User Guide
321
Connect to IP Address a.b.c.d Port n
When using a TCP connection, these text entry boxes allow the user to specify the IP address
and port number that the protocol should use.
Listen on Port
The port number that the router is listening on when in socket mode.
3. Click Apply.
Command line
Command Instance Parameter Values Equivalent web parameter
adapt 0, 1 dial_retries 0-255 Attempt to redial the connection
n times
adapt 0, 1 tinact 0-86400 Drop the connection if it is idle for
h hrs m mins s secs
adapt 0, 1 leased_line off, on Leased line mode
adapt 0, 1 sockmode 0, 1
0=disable
1=enable
Enable TCP rate adaption
adapt 0, 1 ip_addr valid IP
address
a.b.c.d
Connect to IP Address a.b.c.d Port
n
adapt 0, 1 ip_port valid TCP port
number
Connect to IP Address a.b.c.d Port
n
adapt 0, 1 lip_port valid TCP port
number
Listen on Port n