Configuring network interfaces Configure serial interfaces
Digi TransPort® Routers User Guide
332
Configure sending serial data to multiple serial ports
ÉWeb
1. Go to Configuration > Network >Interfaces > Serial >MultiTX > MultiTX Serial Port n.
The MultiTX page is for enabling and setting the MultiTX parameters. This page supports
sending serial data to multiple (up to 5) TCP or UDP destinations. When enabled, the configured
ASY port is opened and serial data from the port is sent to all configured destinations.
2. Configure MultiTX settings:
Enable Multitx
When enabled, displays the MultiTX settings in the web interface and enables the MultiTX
function on the router.
Serial Port
The serial interface to use. Data received on this serial will be forwarded to all configured
remote hosts.
Protocol
Selects the transport method: either TCP or UDP.
Socket Inactivity Timeout
If there is no data transmitted for the specified number of seconds, the socket will be closed.
0=no timeout.
Source port
The source port number.