Configuring network interfaces Configure serial interfaces
Digi TransPort® Routers User Guide
325
Command line
Entity Instance Parameter Values Equivalent web parameter
bind n prot1 Valid protocol, such as PAD 0 Protocol
bind n id1 Valid serial port such as ASY 5 Bound to
Display list of current bindings
To display a list of the current bindings enter the command:
bi nd ?
Bind a V.120 instance 0 to asynchronous serial port 3
bi nd pad 0 asy 0
bi nds PAD 0 t o ser i al por t 0.
bi nd v120 0 asy 3
Access the Internet using PPP
To access the Internet using PPP via a terminal connected to serial interface 2, enter the command:
bi nd ppp 1 asy 2
Bind a TANS instance to an ADAPT instance
Currently it is only possible to bind a TANS instance to an ADAPT instance using the bind command.
The format of the command is:
bi nd adapt <i nst ance> t ans <i nst ance>