Configuring network interfaces Configure PPP and external modems
Digi TransPor Routers User Guide
359
Hang-up string
In a typical wireless application the connection to the network is always on and under normal
circumstances it is not necessary to hang-up the wireless module. Under certain
circumstances however, the router may use the ATH command to try and disconnect the
wireless module from the network, such as if an incorrect APN has been specified and the
module is unable to attach to the network correctly.
This parameter allows you to specify an alternative hang-up string that is sent to the wireless
module when disconnecting a call. As with the Initialization strings, it is not necessary to
include the AT as this is inserted automatically by the router.
Post hang-up string
Additional AT commands that are sent to the wireless module after it has been disconnected.
As with the Initialization strings, it is not necessary to include the AT as this is inserted
automatically by the router.
Listening init string
The listening initialization string parameter for external modems.
Listening init interval (secs)
The listening init string is sent at intervals specified by a listening init interval parameter.
Maximum RING count before answering incoming call
The count of the maximum number of rings before answering incoming call can be set in this
field. The default value is 0.
Minimum RING count before answering incoming call
The count of the minimum number of rings before answering incoming call can be set in this
field. The default value is 0.
3. Click Apply.
Command line
Command Instance Parameter Values Equivalent web parameter
modemcc n asyport 0-255 (Default: 255)
modemcc n init_str Free text field Initialisation string 1
modemcc n init_str1 Free text field Initialisation string 2
modemcc n init_str2 Free text field Initialisation string 3
modemcc n hang_str Free text field Hang-up string
modemcc n posthang_str Free text field Post Hang-up string
modemcc 0 linit_str Free text field Listening init string
modemcc 0 linit_int 0-2147483647 Listening init interval (secs)