Configuring legacy protocols Configure X.25 parameters
Digi TransPor Routers User Guide
635
Disconnect the layer 2 call if there is no layer 3 call in progress for x seconds
The length of time, in seconds, after which the router disconnects a layer 2 link if there are no
layer 3 calls in progress. For LAPB sessions, this also terminates the ISDN call.
Create an event when the following data is on the PAD
A string, which if it appears in the received data causes a Data Trigger (47) event to be
generated and recorded in the event log.
Create an event when there has been no activity on the PAD for x seconds
The time, in seconds, in which if there is no activity on the PAD an event in the event log is
posted. You can use this parameter to trigger email exceptions.
5. Click Apply.
Command line
Command Instance Parameter Values Equivalent web parameter
pad n l2iface lapb, lapd, TCP, SSL Use PAD over interface
pad n l2nb 0-255 (instance of
LAPB or LAPD)
Use PAD over interface
pad n ip_stream 0=off (for XoT),
1=TCP, 2=UDP
Use PAD over interface
pad n defpak 16,32,64,128,256,512
or 1024
Default X.25 packet size
pad n ansnua text (valid NUA) Answer incoming calls from NUA
pad n anscug text (valid CUG) Only answer calls with CUG
pad n amacro text Use X.25 Call Macro macroname to an
ATD command
pad n cingnua text (valid NUA) Use NUA
pad n lcn 1-4095 LCN
pad n lcnup 1=up, 0=down LCN Direction
pad n nuaimode 0=NUI and NUA,
1=NUA only, 2=NUI
only
NUI/NUA selection
pad n dorest 1=enabled,
0=disabled
Enable X.25 Restart Packets
pad n restdel 0 -60000 (ms) Restart delay
pad n IPaddr text Remote IP address