Configuring alarms Configure events to trigger alarms
Digi TransPort® Routers User Guide
682
After power up, wait s seconds before sending Emails, SNMP traps, SMS or
Syslog messages
The delay, in seconds, after power-up that the router should wait before sending any alert
messages. This is useful when the sending of those items would fail if sent too soon after the
router powers up because the underlying interface to use has not completed initialization.
Include event number in the event log and Email, SNMP traps or Syslog
messages
If enabled, event numbers from the logcodes.txt file are included.
3. Click Apply.
Command line
Command Instance Parameter Values Equivalent web parameter
event n loglevel 0-9
0 none
1 low
9 high
Only log events with a log priority of at
least n
event n ev_filter Comma-
separated list of
event numbers
Do not log the following events.
event n action_dly Number of
seconds (such as
60)
After power up, wait s seconds before
sending Email, SNMP traps, SMS or Syslog
messages.
event n incevnums 0, 1 Include event number.