65
ENGINE MANAGEMENT MODULE (EMM)
DIAGNOSTIC SOFTWARE FUNCTIONS
4
Occurred Service Codes (Faults)
Service codes are saved if an abnormal condition
occurs while the outboard is running.
The Occurred Faults scree n of the diagnostics
software shows the code number, the number of
times the event occurred, and operating hours of
first and last occurrences.
Active Faults
An a ctive fau lt is a service code t hat currently
exists. Active faults become occurred faults only if
the outboard is running.
Historical Faults
The Historical Faults screen keeps a history of all
previously saved code s, including cod e number,
the number of times the event occurred, and oper-
ating hours of the last occurrence.
Historical faults cannot be erased.
Static Tests
Static Tests allow dia gnostic testing o f system
components while the outboard is NOT running.
Ignition Test
Use the diagnostics software to test each ig nition
circuit. Refer to Static Ignition Test on p. 81.
Fuel Test
Use the diagnostics sof tware t o te st each fue l
injector circuit. Refer to Fuel Injector Static Test
on p. 84.
Oil Injector
Use the diagnostics software to test the oil injec-
tion pu mp circuit. Refer to OILING SYSTEM
TESTS on p. 166.
Fuel Pump
Use the diagnostics software to test the fuel pump
circuit. Refer to Fuel Pump Static Test on p. 84.
Water Injector
This test activat es the exhaust water valve sole-
noid (60 - 65 HP). Refer to Exhaust Water Valve
Static Test on p. 86.
Occurred Faults Review Screen 008584
Active Faults Review Screen 008585
Static Tests Screen 008569A