Harris Corporation Constellation™
Transmitter Frequency Measurement 8-7
ROUTINE
MAINTENANCE
The power at the top of the rack (TOR) = the power
meter reading + the coupling loss shown on the monitor
port label.
4. If the Power Meter reading does not equal the value calculated from step
3, use the Keypad to adjust the RF power out. Refer to the next section for
a detailed procedure.
5. If power adjustment is required, go to step 6.
If power adjustment is not required, go to step 17.
Table 8-1: Power at antenna flange, NP configuration
TX
Freq.
(GHz)
Power (dBm)
8T 16T 28T/DS3 OC3/3xDS3/4xDS3
Std. High
ab
Std. High
ab
Std. High
a
6 29.5 28.5 29.5 29.0 30.5 29.0 31.5/31.0
c
7/8 27.5 26.5 27.5 27.0 28.5 27.5 30.0
10/11 26.0 24.5 25.5 25.0 26.5 25.0 28.5
a. High Power requires high power option of the Transmit Assembly
b. High power requires high gain modem option (101-115540-002 for 16T and -003 for 28T).
c. The first number is for OC3 & 3xDS3; the second number is for 4xDS3.
Table 8-2: Power at antenna flange, MHSB configuration
TX
Freq.
(GHz)
Power (dBm)
8T 16T 28T/DS3 OC3/3xDS3/4xDS3
Std. High
ab
Std. High
ab
Std. High
a
6 29.1 28.1 29.5 28.6 30.1 28.6 31.1/30.6
c
7/8 27.1 26.1 27.1 26.6 28.1 27.1 29.6
10/11 25.6 24.1 25.1 24.6 26.1 24.6 28.1
a. High Power requires high power option of the Transmit Assembly
b. High power requires high gain modem option (101-115540-002 for 16T and -003 for 28T).
c. The first number is for OC3 & 3xDS3; the second number is for 4xDS3.