Harris Corporation Constellation™
Signal Processing Section 11-27
FIELD-
REPLACEABLE
UNITS
Installing the HLM
1. Check the part number of the HLM to ensure that the correct unit is being
installed.
2. Ensure that the 2 extractors are in the unlocked position.
3. Carefully slide the HLM into the designated slot in the shelf until the unit
plugs into the backplane.
4. Use the 2 extractor tabs to lock the unit into place.
Repeater System
In a repeater system where the Modem units are not the same (that is,
one is 115072 and the other is 115430), ensure that the system
synchronization is set to SOURCE timed.
In a loop system, when the HLM is at a master site, the HLM must be
set to SOURCE timed.
From the Keypad menu, select
CONFIGURATION > SYSTEM > SYNCHRONIZATION MX >
SOURCE
MHSB System
Use the Keypad command to take the switched unit out of lock status.
CONTROL > LOCK/IF LPBK > LOCK HLM, CLR