COMMISSIONING
64 Service Manual Part No.: 4417340 Revision 1
954 SmartServo FlexLine
The TII-SRV firmware supports the following process data commands:
• Water interface dip
• Density tank profile dip
• Density interface profile dip
• Density-Water dip
• Water-density dip
The TII-SRV firmware supports the following displacer action and
diagnostic commands:
• Block
• Freeze
• Find encoder position (calibrate)
• Accept reference
• Unlock
• Test gauge
• Lock test
• Calibrate
• Test
• Lock test to level
• Lock to level
• Go down
• Go up
• Balance test
• Set maintenance mode
• Set operational mode
• Check bearings
• Run down test (free run analyses)
• Servo Auto Test (SAT, check for blockage)
• Alarm test commands
• Frequency calibration (measure frequency)